Separation of Amino acids by TLC Amino acids are the building blocks of peptides
and proteins. They possess two functional groups—the carboxylic acid group that gives
the acidic character, and the amino group that provides the basic character.
The properties provided by these groups are used to characterize the amino acids.
Here, TLC or Thin layer chromatography can be utilized to identify the different amino
acids. Separation occurs as each component, being different in chemical and physical composition,
interacts with the stationary and mobile phases to a different degree creating the individual
spots on the plate.
Here, our aim is to identify an unknown amino acid, by spotting it along with the known
amino acids.
Apparatus: TLC plate, solvent (mobile phase), a mixture of n-butanol, acetic acid and distilled
water in the ratio 12:3:5 , three known amino acids, an unknown mixture of amino acids,
Ninhydrin, a spray bottle, a blow dryer.
Developing a TLC plate requires a developing chamber or vessel called TLC chamber. This
can be as simple as a wide-mouth jar. The chamber should contain enough solvent to just
cover the bottom. It should also contain a piece of filter paper, or other absorbent
material to saturate the atmosphere with solvent vapours. Finally, it should have a lid or
other covering to minimize evaporation.
Procedure: Pour the solvent mixture to the TLC chamber
and close the chamber, The chamber should not be disturbed for about
30 minutes so that the atmosphere in the jar becomes saturated with the solvent vapours.
Cut the plate to the correct size and using a pencil (never ever use a pen); gently draw
a straight line across the plate approximately 1 cm from the bottom.
Using a capillary tube a minute drop of amino acid is spotted on the line.
Allow the spot to dry Spot the second amino acid on the plate [enough
space should be provided between the spots] Repeat the steps to spot the unknown
Place the plate into the TLC chamber as evenly as possible and lean it against the side.
Allow capillary action to draw the solvent up the plate until it is approximately 1 cm
from the end. Remove the plate and immediately draw a pencil
line across the solvent front. Dry the plate with the aid of a blow dryer
Spray the dry plate with ninhydrin reagent. Dry the plates in hot air oven at 105°C for
5 min. [Ninhydrin will react with the spotted amino acids and the resulting complex which
is colored, makes them visible on the plate]. After some time, mark the center of the spots,
then measure the distance of the center of the spots from the origin (base line) and
calculate the Rf values.
Rf value = Distance travelled by the spot [solute front]from the origin
Distance travelled by the mobile phase (solvent front) from the origin
Some tips for a successful result:
Make certain that the spots applied to the plate are above the surface of the eluting
solvent. Cover the TLC chamber with lid to avoid evaporation
of the solvent. Hold the plates by their sides
The solvent front must not advance up to or beyond the edge of the plates