Advertisement
English transcript
Quantitative estimation of amino acids by Ninhydrin Method
Amino acids are known to be the building block of all proteins.
The standard amino acids comprises of a carboxyl group and an amino group bonded to the same
carbon atom (the a carbon).
a-Amino acids are known to react with excess ninhydrin to form a purple colored product,
Ruhemann's purple.
It is one of the most reliable methods for detection of amino acids in their microgram
concentrations
Under appropriate conditions, the color produced is proportional to the amino/imino acid concentration.
Unknown compounds may be identified by their characteristic absorption spectra in the ultraviolet,
visible or infrared regions-graph. A spectrophotometer / colorimeter is an instrument
for measuring the absorbance of a solution by measuring the amount of light of a given
wavelength that is transmitted by a sample.
Reagents required:
Standard amino acid stock solution (150 µg/ml )
Ninhydrin reagent 50% ethanol
Distilled water.
Apparatus and Glasswares required
Test/Boiling tubes Pipettes [glass/micropipette]
Waterbath
Procedure:
Pipette out different volumes (0.2ml-1ml) of standard amino acid solution to the respective
labelled test tubes. Similarly, pipette out 0.8 ml of the same
solution to the testtube, labeled “unknown”. Add distilled water in all test tubes to make
up the volume to 4ml. Add 4ml of distilled water to the test tube
labelled Blank. Now add 1ml of ninhydrin reagent to all test
tubes including Blank and unknown. Mix the contents of the tubes by vortexing
/shaking the tubes. Put a few marble chips in each tube.
Cover the mouth of the tubes with aluminum foil.
Keep all the test tubes in boiling water bath for 15 minutes.
Cool the test tubes in cold water and add 1ml of ethanol to each test tube and mix well.
How to set the colorimeter
Switch on the colorimeter and set the wavelength at 570nm in which the absorbance is to be
measured [about 30 min before taking the readings]. Rinse the cuvette with the blank solution,
drain of the solution by inverting the cuvette and touching it on to the filter paper.
Fill the cuvette to the appropriate mark with the blank solution and keep it in the slot
provided on the colorimeter. Care should be taken that the cuvette is properly
inserted into the slot. Read the OD value and tare the colorimeter
to zero. Take out the cuvette and drain off the blank
solution. Now measure the OD values of the solution
from the lower to the higher concentration.
Amino acids are known to be the building block of all proteins.
The standard amino acids comprises of a carboxyl group and an amino group bonded to the same
carbon atom (the a carbon).
a-Amino acids are known to react with excess ninhydrin to form a purple colored product,
Ruhemann's purple.
It is one of the most reliable methods for detection of amino acids in their microgram
concentrations
Under appropriate conditions, the color produced is proportional to the amino/imino acid concentration.
Unknown compounds may be identified by their characteristic absorption spectra in the ultraviolet,
visible or infrared regions-graph. A spectrophotometer / colorimeter is an instrument
for measuring the absorbance of a solution by measuring the amount of light of a given
wavelength that is transmitted by a sample.
Reagents required:
Standard amino acid stock solution (150 µg/ml )
Ninhydrin reagent 50% ethanol
Distilled water.
Apparatus and Glasswares required
Test/Boiling tubes Pipettes [glass/micropipette]
Waterbath
Procedure:
Pipette out different volumes (0.2ml-1ml) of standard amino acid solution to the respective
labelled test tubes. Similarly, pipette out 0.8 ml of the same
solution to the testtube, labeled “unknown”. Add distilled water in all test tubes to make
up the volume to 4ml. Add 4ml of distilled water to the test tube
labelled Blank. Now add 1ml of ninhydrin reagent to all test
tubes including Blank and unknown. Mix the contents of the tubes by vortexing
/shaking the tubes. Put a few marble chips in each tube.
Cover the mouth of the tubes with aluminum foil.
Keep all the test tubes in boiling water bath for 15 minutes.
Cool the test tubes in cold water and add 1ml of ethanol to each test tube and mix well.
How to set the colorimeter
Switch on the colorimeter and set the wavelength at 570nm in which the absorbance is to be
measured [about 30 min before taking the readings]. Rinse the cuvette with the blank solution,
drain of the solution by inverting the cuvette and touching it on to the filter paper.
Fill the cuvette to the appropriate mark with the blank solution and keep it in the slot
provided on the colorimeter. Care should be taken that the cuvette is properly
inserted into the slot. Read the OD value and tare the colorimeter
to zero. Take out the cuvette and drain off the blank
solution. Now measure the OD values of the solution
from the lower to the higher concentration.