PREPARATION OF BUFFER STOCKS (TBE, TE and TAE)
INTRODUCTION:
Many molecular biology and biochemical reactions are greatly influenced by the concentration
of free H+ ions, i.e., pH, of a solution. So it is necessary to stabilize the pH of
the reaction mixture by adding suitable buffers. A buffer is a solution which resists changes
in the pH value. There are two types of buffer solutions: Acidic and Basic. Acidic buffers
with pH less than 7 are prepared from a weak acid and one of its salts with a strong base.
An alkaline buffer having pH greater than 7 is made from a weak base and one of its
salts with a strong acid. Most of molecular biology techniques rely on buffers like Tris
Acetate EDTA (TAE), Tris Borate EDTA (TBE) and Tris EDTA (TE) especially for agarose
gel electrophoresis and storage of nucleic acids respectively.
Materials required:
Cotton Spatula
Butter paper Forceps
200ml beaker 1000ml beakers(labeled as TE Buffer, 5X TBE
Buffer and 10X TAE Buffer) Distilled water
Measuring cylinders of 100ml , 1000ml, 50ml and 10ml
Waste beaker Glass rod
Weighing balance 1M Tris-HCl
0.5M EDTA 0.1 M Hydrochloric acid (HCl)
Glacial acetic acid Tris base
1 N NaOH Reagent bottles (labeled as TE Buffer, 5X
TBE Buffer and 10X TAE Buffer) Glass pipette (2ml)
Pipette pump Boric acid
PROCEDURE:
Preparation of 10X TAE Buffer
Take a clean spatula, wipe it with cotton, and weigh out 48.4g of Tris base. After weighing,
add this into an empty beaker labeled as TAE buffer.
Take a measuring cylinder of 50ml and rinse it well.
Take 11.4ml of Glacial acetic acid using a measuring cylinder and transfer it into the
beaker labeled as TAE Buffer. Wash the measuring cylinder under tap water
and keep it on the work bench. Rinse the measuring cylinder (50ml) with distilled
water. Take 20ml of 0.5M EDTA solution using the
measuring cylinder. Add 20ml of EDTA solution into the beaker
labeled as TAE Buffer. Take a measuring cylinder of 1000ml and rinse
it well. Pour approximately 600ml of distilled water
into the measuring cylinder and transfer it into the beaker labeled as TAE Buffer.
Take a glass rod, wipe it with cotton and then mix the solution with it.
Transfer the solution into the 1000ml measuring cylinder.
Add a small amount of distilled water into the beaker labeled as TAE buffer (empty) and
swirl it well. Transfer the solution into the 1000ml measuring
cylinder. Adjust the final volume to 1000ml with distilled
water. Transfer the entire solution into a reagent
bottle (TAE Buffer).
Preparation of TE Buffer
Take a measuring cylinder of 10ml and rinse it well.
Measure 10ml of 1M Tris –Cl from the bottle. Transfer the measured tris-cl buffer solution
into a 1000 ml beaker labeled as TE buffer. Take a 2ml glass pipette from the rack and
insert a pipette pump into it. Pipette out 2ml of 0.5M EDTA solution and
transfer it into the beaker labeled as TE buffer.
Take a measuring cylinder of 1000ml and rinse it well.
Pour 600ml of distilled water into the measuring cylinder and transfer it into the beaker labeled
as TE Buffer. Wipe a glass rod with cotton and then use
it to mix the solution. Transfer the solution into the 1000ml(1L)
measuring cylinder. Add a small amount of distilled water into
the beaker labeled as TE buffer (empty) and rinse it well.
Transfer the solution into the 1000ml(1L) measuring cylinder.
Adjust the final volume to 1000ml with distilled water.
This 1000ml of TE buffer is transferred into a reagent bottle labeled as TE buffer.
Preparation of 5X TBE Buffer
Take a clean spatula, wipe it with cotton, then open the Tris base bottle and take it
up to 54g . After weighing, pour this into an empty beaker labeled as TBE buffer.
Take a new clean spatula, wipe it with cotton, then open the boric acid bottle and take it
up to 27.5g . After weighing , add this to the beaker labeled as TBE buffer
Take a measuring cylinder of 25ml and add a little of distilled water and rinse it well
and pour the water into the sink. Open the bottle and take 20ml of 0.5M EDTA
solution with a measuring cylinder of 20ml. Add 20ml of EDTA solution in to the beaker
labeled as TBE Buffer. Wash the measuring cylinder under tap water
and place it on the work bench. Take a measuring cylinder of 1000ml, add a
little distilled water and rinse it well and pour the water into the sink.
Take 600ml of distilled water in the measuring cylinder and transfer it into the beaker labeled
as TBE Buffer. Take a glass rod, wipe it with cotton and
then mix the solution with it. Transfer the solution into the 1000ml(1L)
measuring cylinder. Pour a small amount of distilled water in
the beaker labeled as TBE buffer (empty) and rinse it well.
Transfer the solution into the 1000ml(1L) measuring cylinder.
Adjust the final volume to 1000ml with distilled water.
Transfer the solution into a reagent bottle labeled as TBE buffer.